Skip to content

Center for Nuclear Magnetic Resonance Spectroscopy

University of Florida, Chemistry Department

Menu
  • New Users
    • Policies
    • Safety
    • Getting Trained
    • Facility Layout
    • Prices
  • Instruments
    • Bruker 600 MHz (b600)
    • Bruker 400 MHz (b400)
    • Inova 500 MHz 2 RF channels (i2c)
    • Inova 500 MHz 3 RF channels (i3c)
    • Agilent 600 MHz
  • Reserve Time
    • Signup Rules
  • Software
  • Trainings
  • Supplies
    • NMR tubes
    • Deuterated solvents
  • Contact us
  • Internal docs
    • REFILLS
    • WEBSITE
    • SIGNUP
    • BRUKER
    • VARIAN
Menu

NMR Probes

300 MHz probes

Can be shared between the two Mercury instruments

  • 4nuc Varian 5 mm quadruply tuned probe H1/F19/C13/P31 alternately H1/F19/P31-N15.a z-axis gradients. Temperature range -20 to 80 °C.
  • asw Varian 5 mm quadruply tuned probe H1/F19/C13/P31 alternately H1/F19/P31-N15.a z-axis gradients. Temperature range -100 to 130 °C.
  • atb Varian 5 mm triply tuned probe H1/F19/P31-N15.a z-axis gradients. Temperature range -100 to 130 °C.
  • id Narolac 5 mm indirect detection probe H1-F19/P31-N15. z-axis gradients. Temperature range -20 to 80 °C.

a This notation means that the high band channel is simultaneously tuned to H1 and F19, while the low band channel is tuned to a nucleus in the frequency range P31-N15.

 

500 MHz probes

can be sharedb between the two Inova instruments

  • id3 Varian 5 mm triple resonance indirect detection probe H1/C13/P31-N15.c z-axis gradients. Temperature range -100 to 130 °C.
  • fid3 Varian 5 mm triple resonance indirect detection probe H1-F19/C13/P31-N15.c z-axis gradients. Temperature range -20 to 80 °C.
  • id2 Varian 5 mm indirect detection probe H1/P31-N15.d z-axis gradients. Temperature range -100 to 130 °C.
  • sw2 Varian 5 mm conventional probe H1/P31-N15.d z-axis gradients. Temperature range -100 to 150 °C.
  • nano Varian gHX indirect detection nanoprobe H1/P31-N15.d z-axis gradients. Temperature range 0 to 50 °C. This is a special probe with magic angle spinning and rotors with a volume of 50 ml; to be used for inhomogeneous samples such as swollen resins.
  • id Varian 5 mm indirect detection probe H1/P31-N15. No gradients. Temperature range -100 to 130 °C.

b You will make full use of the triple resonance probes on i3c, which has 3 RF channels.

c This notation means that the high band channel is tuned to H1, the second channel is tuned to C13, and the third channel is tuned to a nucleus in the frequency range P31-N15 (default N15).

d This notation means that the high band channel is tuned to H and the second channel is tuned to a nucleus in the frequency range P31-N15 (default C13).

news

  • Upcoming trainings August 29, 2025
  • How to estimate the duration of other experiments based on a proton spectrum August 7, 2025
  • Upcoming trainings June 20, 2025
  • Upcoming trainings June 13, 2025
  • Variable temperature training May 16, 2025
©2025 Center for Nuclear Magnetic Resonance Spectroscopy | Built using WordPress and Responsive Blogily theme by Superb