Skip to content

Center for Nuclear Magnetic Resonance Spectroscopy

University of Florida, Chemistry Department

Menu
  • New Users
    • Policies
    • Safety
    • Getting Trained
    • Facility Layout
    • Prices
  • Instruments
    • Bruker 600 MHz (b600)
    • Bruker 400 MHz (b400)
    • Inova 500 MHz 2 RF channels (i2c)
    • Inova 500 MHz 3 RF channels (i3c)
    • Agilent 600 MHz
  • Reserve Time
    • Signup Rules
  • Software
  • Trainings
  • Supplies
    • NMR tubes
    • Deuterated solvents
  • Contact us
  • Internal docs
    • REFILLS
    • WEBSITE
    • SIGNUP
    • BRUKER
    • VARIAN
Menu

Author: Ion Ghiviriga

Upcoming trainings

Posted on August 29, 2025August 29, 2025 by Ion Ghiviriga
Basic operation training on Tuesday September 2nd at 1300 in CLB110. Bruker training of Friday September 5th at 1300 in CLB110.

How to estimate the duration of other experiments based on a proton spectrum

Posted on August 7, 2025 by Ion Ghiviriga
This will depend on the instrument. The tutorial for b600 is here. First step is to estimate the concentration of the sample based on the residual signal of the solvent. Knowing how long it takes on that instrument to achieve a signal to noise ratio (SNR) in a particular experiment on a sample of known…

Upcoming trainings

Posted on June 20, 2025 by Ion Ghiviriga
Bruker training on Wednesday June 25 at 1300 in clb110. 2D training on Thursday June 26 at 1300 in clb110.

Upcoming trainings

Posted on June 13, 2025June 13, 2025 by Ion Ghiviriga
Basic operation training on Friday June 20th at 1300 in clb110. Bruker training on Wednesday June 25th at 1300 in clb110.

Variable temperature training

Posted on May 16, 2025 by Ion Ghiviriga
on Tuesday May 20th at 1000 in clb110.

Bruker training

Posted on May 16, 2025 by Ion Ghiviriga
on Monday May 19 at 1300 in clb110.

Upcoming trainings

Posted on May 8, 2025May 8, 2025 by Ion Ghiviriga
Basic operation training on Monday May 12 at 1300 in clb110 Bruker training on Wednesday May 14 at 1300 in clb110.

2D training

Posted on April 29, 2025April 29, 2025 by Ion Ghiviriga
on Thursday May 1st in clb110.

Upcoming trainings

Posted on March 20, 2025March 20, 2025 by Ion Ghiviriga
Bruker training on Monday March 24th at 1300 in clb110. Basic operation training on Tuesday March 25th at 1300 in clb110.

Upcoming trainings

Posted on February 24, 2025 by Ion Ghiviriga
Bruker training Wednesday February 26th at 1100 in clb110. Basic operation training Thursday February 27th at 1300 in clb110.

Posts pagination

  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • …
  • 13
  • Next

news

  • Upcoming trainings September 24, 2026
  • Upcoming Trainings September 15, 2026
  • Trainings this week July 20, 2026
  • Upcoming trainings May 8, 2026
  • Trainings this week April 13, 2026
©2026 Center for Nuclear Magnetic Resonance Spectroscopy | Built using WordPress and Responsive Blogily theme by Superb