Skip to content

Center for Nuclear Magnetic Resonance Spectroscopy

University of Florida, Chemistry Department

Menu
  • New Users
    • Policies
    • Safety
    • Getting Trained
    • Facility Layout
    • Prices
  • Instruments
    • Bruker 600 MHz (b600)
    • Bruker 400 MHz (b400)
    • Inova 500 MHz 2 RF channels (i2c)
    • Inova 500 MHz 3 RF channels (i3c)
    • Agilent 600 MHz
  • Reserve Time
    • Signup Rules
  • Software
  • Trainings
  • Supplies
    • NMR tubes
    • Deuterated solvents
  • Contact us
  • Internal docs
    • REFILLS
    • WEBSITE
    • SIGNUP
    • BRUKER
    • VARIAN
Menu

Category: News

b400 and i3c now open for users

Posted on November 3, 2020November 3, 2020 by Ion Ghiviriga
As a next step in research resumption, the i3c in clb108 and the b400 in clb110 are now open for users, in the conditions bellow: Users have been trained on these instruments. If you need training, contact Ion. To use the i3c, sent an email to Robert before, and he will update your account. You…

Added runs on Sunday

Posted on September 17, 2020September 17, 2020 by Ion Ghiviriga
Starting this weekend, we’ll do two runs on Sunday, at 1300 and 1600.

Labor Day runs

Posted on September 4, 2020September 4, 2020 by Ion Ghiviriga
We will treat Labor Day as a Sunday, one run at 1500.

New schedule for the service runs

Posted on August 31, 2020August 31, 2020 by Ion Ghiviriga
Starting this week, we added more runs on weekends. The new schedule is: M-F 1000, 1300, 1500, 1700, 1900, 2200; Sat 1300, 1600, 1900; Sun 1500.

New schedule for the runs

Posted on July 31, 2020 by Ion Ghiviriga
Starting Monday, August 3rd: We are adding another run in the afternoon, to accommodate the influx of samples. The new schedule is 1000, 1300, 1500, 1700, 1900, 2200. Samples taking more than 5 minutes (that’s time for a proton in16 scans and a carbon in 64) might be moved to the night run, depending on…

Mnova Q&A session on Friday at 1100

Posted on July 29, 2020July 29, 2020 by Ion Ghiviriga
I will organize a zoom meeting to answer your questions on Mnova processing. I already have a list of questions, and I would also discuss processing kinetics in Mnova, but this is an opportunity to submit your own questions, preferably by email, and preferably ahead of the session.

Sample submission form and data directory

Posted on July 28, 2020 by Ion Ghiviriga
Dear All, here is a reminder about the sample submission form and the directory where you can find your data: Remember the location of your samples in the tray (take picture?) , return to your lab and fill in the Sample Submission Form. Once your samples are run, you can retrieve the data from the…

As the number of submitted samples increases

Posted on July 11, 2020July 11, 2020 by Ion Ghiviriga
use the second row in the sample submission tray. When location 24 is taken, continue with the inner row of position 1 and fill the sample submission form as location 1′. Also, starting Saturday July 18, we will not accept long J-Young tubes anymore.

Submitting samples

Posted on June 9, 2020June 9, 2020 by Ion Ghiviriga
As the number of samples increases, please follow these directions to streamline the runs: The height of the solvent in the tube should be at least 40 mm.Write the sample identifier on the tube, with a fine marker. You can buy those at the stockroom. You can erase the writing after, with acetone. No more…

Weekend Runs

Posted on June 5, 2020June 5, 2020 by Ion Ghiviriga
We will have two runs on Saturday at 1300 and 1900. Submit your samples as usual, using the Sample Submission Form.

Posts pagination

  • Previous
  • 1
  • …
  • 8
  • 9
  • 10
  • 11
  • 12
  • Next

news

  • Trainings for the week of January 25 January 21, 2026
  • Upcoming trainings January 15, 2026
  • Upcoming trainings January 9, 2026
  • Training on quantitative NMR with external reference. January 6, 2026
  • basic operation training January 5, 2026
©2026 Center for Nuclear Magnetic Resonance Spectroscopy | Built using WordPress and Responsive Blogily theme by Superb