Skip to content

Center for Nuclear Magnetic Resonance Spectroscopy

University of Florida, Chemistry Department

Menu
  • New Users
    • Policies
    • Safety
    • Getting Trained
    • Facility Layout
    • Prices
  • Instruments
    • Bruker 600 MHz (b600)
    • Bruker 400 MHz (b400)
    • Inova 500 MHz 2 RF channels (i2c)
    • Inova 500 MHz 3 RF channels (i3c)
    • Agilent 600 MHz
  • Reserve Time
    • Signup Rules
  • Software
  • Trainings
  • Supplies
    • NMR tubes
    • Deuterated solvents
  • Contact us
  • Internal docs
    • REFILLS
    • WEBSITE
    • SIGNUP
    • BRUKER
    • VARIAN
Menu

Category: News

Operation during Stage 2 of the Research Resumption

Posted on June 3, 2020June 5, 2020 by Ion Ghiviriga
Users are still not allowed to enter the NMR rooms, but they submit/retrieve samples in/from the trays outside CLB110. You do not have to book time for submitting/retrieving samples anymore, but conform to the University rules while on the hallway, i.e. face mask and 6 ft away. For the time being, we organize at least…

J-Young tubes for the autosampler

Posted on May 28, 2020June 5, 2020 by Ion Ghiviriga
The ordinary J-Young tubes are too long for the autosampler. You can still submit samples in them, but they’ll be run manually on the B400 during 0800-1600 M-F. I recommend you buy these shorter J-Young tubes: https://www.wilmad-labglass.com/Products/535-LPV-200M/ for New Era CAV tubes specify L=135 mm https://newera-spectro.com/controlled-atmosphere-valve-cav

Operations during Stage 1 of the Research Resumption

Posted on May 21, 2020June 5, 2020 by Ion Ghiviriga
The Center for NMR Spectroscopy will reopen on Tuesday, May 26, observing social distancing. Users will not be allowed in the NMR rooms, but will leave and pick-up their samples on the corresponding trays at the door to CLB110. Use the signup for B600 and do the drop/pickup at the beginning of the 10 minutes…

Posts pagination

  • Previous
  • 1
  • …
  • 9
  • 10
  • 11
  • 12

news

  • Trainings for the week of January 25 January 21, 2026
  • Upcoming trainings January 15, 2026
  • Upcoming trainings January 9, 2026
  • Training on quantitative NMR with external reference. January 6, 2026
  • basic operation training January 5, 2026
©2026 Center for Nuclear Magnetic Resonance Spectroscopy | Built using WordPress and Responsive Blogily theme by Superb